authorV3n3RiX <venerix@koprulu.sector>2024-01-01 05:52:14 +0000
committerV3n3RiX <venerix@koprulu.sector>2024-01-01 05:52:14 +0000
commitbcc717ffe9cc7dccbea636cefb524a54429ed3c5 (patch)
tree86b68b64cb19bcf8d3c1fb98fc9ca858dc6b0e46 /sys-power
parentbf90f82fef4fc737c88b58cd31428ad4355c17fa (diff)
gentoo auto-resync : 01:01:2024 - 05:52:14
Diffstat (limited to 'sys-power')
-rw-r--r--sys-power/Manifest.gzbin5741 -> 5742 bytes
-rw-r--r--sys-power/nut/Manifest3
-rw-r--r--sys-power/nut/nut-2.8.0-r3.ebuild220
-rw-r--r--sys-power/nut/nut-9999.ebuild3
4 files changed, 223 insertions, 3 deletions
diff --git a/sys-power/Manifest.gz b/sys-power/Manifest.gz
index 27b64af8c112..e328b2b03d39 100644
--- a/sys-power/Manifest.gz
+++ b/sys-power/Manifest.gz
Binary files differ
diff --git a/sys-power/nut/Manifest b/sys-power/nut/Manifest
index e8616a6e705f..810ab570eb9e 100644
--- a/sys-power/nut/Manifest
+++ b/sys-power/nut/Manifest
@@ -16,5 +16,6 @@ DIST nut-2.7.4.tar.gz 2509831 BLAKE2B 367c687efd739150898a14c700d5fddbe22bf92652
DIST nut-2.8.0.tar.gz 3287640 BLAKE2B 6ad87e9c90920d45846d9c1311e8feeb3c36bfa506d62d938940c00d2fc7f7b30632d079a8ee969db624824ae4fd3e14e41e8acd1eda296e26a3aa340f186b94 SHA512 3c413ae54088045a713eb80cf1bdda474f41bb3b67c7c0248aa7a0c4d441dce1ff42627a2735273d7e36892d1f2eeb895220cf28af63fec2fa0c7a267f82d577
EBUILD nut-2.7.4-r8.ebuild 8839 BLAKE2B df9cfb0d44952cf6847964a15721153a57f4effd146ef9f9ffcff29c87a09038167ff74009a086132d21a06ae72a16a6c39758eb2cbe59e6eb1b4a660ccb3e7a SHA512 8cae8d96ad22e44ba3594ee09e399dee5a566e5e16b140a5fd707d2f4efc794655fa6cf83602ba4c3a7667cb304294a7b3898ed28812a0ec56dad01e26312fd0
EBUILD nut-2.8.0-r2.ebuild 5809 BLAKE2B 2510c9c9d956543bc5e0f3b631af9531c2967526c9faad83bd0cf68dba9345b765479287bb680b0fd04978a78451c2199bcf2d0a9a94a7a94c6d7423dd4ea282 SHA512 5f37c10321d8f13b337be4559480f6493b87833430f540eab03574398496355e4d0c9631fcd539e52f12e88164c7b8b133985b77df3ac3aab8e4a022307422ac
-EBUILD nut-9999.ebuild 6953 BLAKE2B 4b735c2c227c0f2cb8ff0d45573d215fc1ea663ffdc5badc9564a41c5dc7e876b1475ea028e6a583ce69f3b7bb24e8a4e62e6278719f5a9c46177ae07fbedfec SHA512 b42b686b8366ed8ec7388d24667b458cae62f849aa894b2fa9c7982e23145be934d23485ceef2d7093b8ed2de7a4a7f446e362ce89cf1e79b55aa4ebdcba45b8
+EBUILD nut-2.8.0-r3.ebuild 5740 BLAKE2B 40e0b04933a6f2bf78c11f9f25a14a9a87eae973fc10736f6c02970842abdfbc3ce1eba6633504815ff227274430dd6f89d140eef43fcbaa6250070f8bceae34 SHA512 76c2520ca5d3052ab2d750697d62263e6b7b62c8f3d5f0cb709028283f072c0e2daa62b3ce025eceec6251a9c68a785ec674e4abc8a9c5664555391743a6760f
+EBUILD nut-9999.ebuild 6881 BLAKE2B 3be9c0da9c89ad7b6bbc1a51d3b85d21a2462b5caea152dc4b0356005494cd7329f5d4156e696e5ca11824d0036d2519f28771977f240672900401b2b4fffd36 SHA512 1f2f2ad0a4d9ef14a125fd4cc8c7e589a994b36d1315d0c7639b3b85c11572bd765242babbe238348d1868ea98c69e934d1b4b2cc52d383a2b5c85251f7a645f
MISC metadata.xml 6068 BLAKE2B 499dd975b0364733e71175eb061d935f754343d32d6eba547a26659438a0488a25509e907516b73d7bfd9714be28bc2159dd8688d2578611c9b9fca419881446 SHA512 cc42c7645c78516a2b2e82ec09098c88c1f7fbcc68f5685906811b9182dd4869c31c4eb865c5deab8cc105cf24e32161cf7db746fe793e6bea08fbf12f561e79
diff --git a/sys-power/nut/nut-2.8.0-r3.ebuild b/sys-power/nut/nut-2.8.0-r3.ebuild
new file mode 100644
index 000000000000..20eea7107c63
--- /dev/null
+++ b/sys-power/nut/nut-2.8.0-r3.ebuild
@@ -0,0 +1,220 @@
+# Copyright 1999-2023 Gentoo Authors
+# Distributed under the terms of the GNU General Public License v2
+
+EAPI=8
+
+inherit bash-completion-r1 flag-o-matic linux-info optfeature systemd
+inherit tmpfiles toolchain-funcs udev
+
+MY_P=${P/_/-}
+
+DESCRIPTION="Network-UPS Tools"
+HOMEPAGE="https://networkupstools.org/"
+
+if [[ ${PV} == *9999 ]] ; then
+ EGIT_REPO_URI="https://github.com/networkupstools/${PN}.git"
+ inherit git-r3
+else
+ SRC_URI="https://networkupstools.org/source/${PV%.*}/${MY_P}.tar.gz"
+ KEYWORDS="~amd64 ~arm ~arm64 ~ppc ~ppc64 ~riscv ~x86"
+fi
+
+S="${WORKDIR}/${MY_P}"
+
+LICENSE="GPL-2"
+SLOT="0"
+IUSE="cgi doc ipmi serial i2c +man snmp +usb modbus selinux ssl tcpd test xml zeroconf"
+RESTRICT="!test? ( test )"
+
+DEPEND="
+ acct-group/nut
+ acct-user/nut
+ dev-libs/libltdl
+ virtual/udev
+ cgi? ( >=media-libs/gd-2[png] )
+ i2c? ( sys-apps/i2c-tools )
+ ipmi? ( sys-libs/freeipmi )
+ modbus? ( dev-libs/libmodbus )
+ snmp? ( net-analyzer/net-snmp:= )
+ ssl? ( >=dev-libs/openssl-1:= )
+ tcpd? ( sys-apps/tcp-wrappers )
+ usb? ( virtual/libusb:1 )
+ xml? ( >=net-libs/neon-0.25.0:= )
+ zeroconf? ( net-dns/avahi )
+"
+BDEPEND="
+ virtual/pkgconfig
+ man? ( app-text/asciidoc )
+ test? ( dev-util/cppunit )
+"
+RDEPEND="
+ ${DEPEND}
+ selinux? ( sec-policy/selinux-nut )
+"
+
+PATCHES=(
+ "${FILESDIR}/${PN}-2.6.2-lowspeed-buffer-size.patch"
+)
+
+pkg_pretend() {
+ if use i2c; then
+ CONFIG_CHECK="~I2C_CHARDEV"
+ ERROR_I2C_CHARDEV="You must enable I2C_CHARDEV in your kernel to continue"
+ fi
+ if use usb; then
+ CONFIG_CHECK+=" ~HIDRAW ~USB_HIDDEV"
+ ERROR_HIDRAW="HIDRAW is needed to support USB UPSes"
+ ERROR_I2C_CHARDEV="USB_HIDDEV is needed to support USB UPSes"
+ fi
+ if use serial; then
+ CONFIG_CHECK="~SERIAL_8250"
+ ERROR_SERIAL_8250="SERIAL_8250 is needed to support Serial UPSes"
+ fi
+
+ # Now do the actual checks setup above
+ check_extra_config
+}
+
+src_prepare() {
+ default
+
+ if [[ ${PV} == *9999 ]] ; then
+ ./autogen.sh || die
+ fi
+}
+
+src_configure() {
+ local myeconfargs=(
+ --datadir=/usr/share/nut
+ --datarootdir=/usr/share/nut
+ --disable-static
+ --disable-strip
+ --disable-Werror
+ --sysconfdir=/etc/nut
+ --with-dev
+ --with-drvpath="/$(get_libdir)/nut"
+ --with-group=nut
+ --with-htmlpath=/usr/share/nut/html
+ --with-logfacility=LOG_DAEMON
+ --with-statepath=/var/lib/nut
+ --with-systemdsystemunitdir="$(systemd_get_systemunitdir)"
+ --with-systemdtmpfilesdir="/usr/lib/tmpfiles.d"
+ --with-udev-dir="$(get_udevdir)"
+ --with-user=nut
+ --without-powerman
+ --without-python
+ --without-python2
+ --without-python3
+ --with-altpidpath=/run/nut
+ --with-pidpath=/run/nut
+ $(use_enable test cppunit)
+ $(use_with cgi)
+ $(use_with i2c linux_i2c)
+ $(use_with ipmi freeipmi)
+ $(use_with ipmi)
+ $(use_with serial)
+ $(use_with snmp)
+ $(use_with ssl)
+ $(use_with tcpd wrap)
+ $(use_with usb)
+ $(use_with xml neon)
+ $(use_with zeroconf avahi)
+ )
+
+ filter-lto
+ append-flags -fno-lto
+ tc-export CC CXX AR
+
+ use cgi && myeconfargs+=( --with-cgipath=/usr/share/nut/cgi )
+ use man && myeconfargs+=( --with-doc=man )
+
+ export bashcompdir="$(get_bashcompdir)"
+
+ econf "${myeconfargs[@]}"
+}
+
+src_install() {
+ default
+
+ rm -rf "${ED}/etc/hotplug" || die
+
+ find "${ED}" -name '*.la' -delete || die
+
+ dodir /sbin
+
+ if use cgi; then
+ elog "CGI monitoring scripts are installed in ${EPREFIX}/usr/share/nut/cgi."
+ elog "copy them to your web server's ScriptPath to activate (this is a"
+ elog "change from the old location)."
+ elog "If you use lighttpd, see lighttpd_nut.conf in the documentation."
+ elog
+ elog "Use script aliases according to the web server you use (apache, nginx, lighttpd, etc...)"
+ fi
+
+ # This must be done after all of the install phases
+ local i
+ for i in "${ED}"/etc/nut/*.sample ; do
+ mv "${i}" "${i/.sample/}" || die
+ done
+
+ local DOCS=( AUTHORS MAINTAINERS NEWS README TODO UPGRADING )
+ einstalldocs
+
+ if use doc; then
+ newdoc lib/README README.lib
+ dodoc docs/*.txt
+ docinto cables
+ dodoc docs/cables/*
+ fi
+
+ newinitd "${FILESDIR}"/nut-2.8.0-init.d-upsd upsd
+ newinitd "${FILESDIR}"/nut-2.2.2-init.d-upsdrv upsdrv
+ newinitd "${FILESDIR}"/nut-2.6.5-init.d-upsmon upsmon
+ newinitd "${FILESDIR}"/nut-2.6.5-init.d-upslog upslog
+ newinitd "${FILESDIR}"/nut.powerfail.initd nut.powerfail
+
+ newbashcomp "${S}"/scripts/misc/nut.bash_completion upsc
+ bashcomp_alias upsc upscmd upsd upsdrvctl upsmon upsrw
+
+ if use zeroconf; then
+ insinto /etc/avahi/services
+ doins scripts/avahi/nut.service
+ fi
+
+ mv "${ED}"/usr/lib/tmpfiles.d/nut-common.tmpfiles "${ED}"/usr/lib/tmpfiles.d/nut-common-tmpfiles.conf || die
+
+ # Fix double directory
+ sed -i -e 's:/nut/nut:/nut:g' "${ED}"/usr/lib/tmpfiles.d/nut-common-tmpfiles.conf || die
+}
+
+pkg_postinst() {
+ elog "Please note that NUT now runs under the 'nut' user."
+ elog "NUT is in the uucp group for access to RS-232 UPS."
+ elog "However if you use a USB UPS you may need to look at the udev or"
+ elog "hotplug rules that are installed, and alter them suitably."
+ elog
+ elog "You are strongly advised to read the UPGRADING file provided by upstream."
+ elog
+ elog "Please note that upsdrv is NOT automatically started by upsd anymore."
+ elog "If you have multiple UPS units, you can use their NUT names to"
+ elog "have a service per UPS:"
+ elog "ln -s /etc/init.d/upsdrv /etc/init.d/upsdrv.\$UPSNAME"
+ elog
+ elog 'If you want apcupsd to power off your UPS when it'
+ elog 'shuts down your system in a power failure, you must'
+ elog 'add nut.powerfail to your shutdown runlevel:'
+ elog
+ elog 'rc-update add nut.powerfail shutdown'
+ elog
+
+ optfeature "all notify events generate a global message (wall) to all users, plus they are logged via the syslog" \
+ sys-apps/util-linux[logger,tty-helpers]
+
+ udev_reload
+
+ tmpfiles_process nut-common-tmpfiles.conf
+}
+
+pkg_postrm() {
+ udev_reload
+}
diff --git a/sys-power/nut/nut-9999.ebuild b/sys-power/nut/nut-9999.ebuild
index a56635519b2d..22a0e6bc597a 100644
--- a/sys-power/nut/nut-9999.ebuild
+++ b/sys-power/nut/nut-9999.ebuild
@@ -24,7 +24,7 @@ S="${WORKDIR}/${MY_P}"
LICENSE="GPL-2"
SLOT="0"
-IUSE="gpio cgi doc ipmi serial i2c +man snmp +usb modbus selinux split-usr ssl tcpd test xml zeroconf python monitor systemd"
+IUSE="gpio cgi doc ipmi serial i2c +man snmp +usb modbus selinux ssl tcpd test xml zeroconf python monitor systemd"
RESTRICT="!test? ( test )"
REQUIRED_USE="
@@ -170,7 +170,6 @@ src_install() {
find "${ED}" -name '*.la' -delete || die
dodir /sbin
- use split-usr && dosym ../usr/sbin/upsdrvctl /sbin/upsdrvctl
if use cgi; then
elog "CGI monitoring scripts are installed in ${EPREFIX}/usr/share/nut/cgi."