summaryrefslogtreecommitdiff
path: root/sys-apps/sysvinit/files/sysvinit-2.99-shutdown-h.patch
diff options
context:
space:
mode:
Diffstat (limited to 'sys-apps/sysvinit/files/sysvinit-2.99-shutdown-h.patch')
-rw-r--r--sys-apps/sysvinit/files/sysvinit-2.99-shutdown-h.patch82
1 files changed, 82 insertions, 0 deletions
diff --git a/sys-apps/sysvinit/files/sysvinit-2.99-shutdown-h.patch b/sys-apps/sysvinit/files/sysvinit-2.99-shutdown-h.patch
new file mode 100644
index 000000000000..a4ceeda69c5f
--- /dev/null
+++ b/sys-apps/sysvinit/files/sysvinit-2.99-shutdown-h.patch
@@ -0,0 +1,82 @@
+other inits have moved to not requiring the -h flag when used with -H/-P.
+modify sysvinit to be the same since it really doesn't matter.
+
+https://bugs.gentoo.org/449354
+
+patch by Doug Goldstein
+
+--- sysvinit-2.99/man/shutdown.8
++++ sysvinit-2.99/man/shutdown.8
+@@ -66,22 +66,19 @@
+ .\"}}}
+ .\"{{{ -h
+ .IP \fB\-h\fP
+-Halt or power off after shutdown. Usually used with the \fI-P\fP or \fI-H\fP flags,
+-depending on whether we want to poweroff or simply stop the operating system.
++Equivalent to \fI-P\fP, unless \fI-H\fP is specified.
+ .\"}}}
+ .\"{{{ -P
+ .IP \fB\-P\fP
+-Modifier to the \fI-h\fP flag. Halt action is to turn off the power.
+-Must be used with the \fI-h\fP flag.
++Halt action is to turn off the power.
+ .\"}}}
+ .\"{{{ -H
+ .IP \fB\-H\fP
+-Modifier to the \fI-h\fP flag. Halt action is to halt or drop into boot
+-monitor on systems that support it. Must be used with the \fI-h\fP flag.
++Action is to halt or drop into boot monitor on systems that support it.
+ Halting is often used to run through the shutdown process and leave
+ output on the screen for debugging purposes. Or when the user wants the OS to
+ stop, but leave the power on. To power off at the end of the shutdown sequence
+-use the \fI-P\fP modifier instead.
++use the \fI-P\fP option instead.
+ .\"}}}
+ .\"{{{ -f
+ .IP \fB\-f\fP
+--- sysvinit-2.99/src/shutdown.c
++++ sysvinit-2.99/src/shutdown.c
+@@ -144,9 +144,7 @@
+ "\t\t -r: reboot after shutdown.\n"
+ "\t\t -h: halt after shutdown.\n"
+ "\t\t -P: halt action is to turn off power.\n"
+- "\t\t can only be used along with -h flag.\n"
+ "\t\t -H: halt action is to just halt.\n"
+- "\t\t can only be used along with -h flag.\n"
+ "\t\t -f: do a 'fast' reboot (skip fsck).\n"
+ "\t\t -F: Force fsck on reboot.\n"
+ "\t\t -n: do not go through \"init\" but go down real fast.\n"
+@@ -556,9 +554,11 @@
+ switch(c) {
+ case 'H':
+ halttype = "HALT";
++ down_level[0] = '0';
+ break;
+ case 'P':
+ halttype = "POWEROFF";
++ down_level[0] = '0';
+ break;
+ case 'a': /* Access control. */
+ useacl = 1;
+@@ -574,6 +574,8 @@
+ break;
+ case 'h': /* Halt after shutdown */
+ down_level[0] = '0';
++ if (!halttype)
++ halttype = "POWEROFF";
+ break;
+ case 'f': /* Don't perform fsck after next boot */
+ fastboot = 1;
+@@ -613,12 +615,6 @@
+ }
+ }
+
+- if (NULL != halttype && down_level[0] != '0') {
+- fprintf(stderr, "shutdown: -H and -P flags can only be used along with -h flag.\n");
+- usage();
+- exit(1);
+- }
+-
+ /* Do we need to use the shutdown.allow file ? */
+ if (useacl && (fp = fopen(SDALLOW, "r")) != NULL) {
+